3
Power on
Indicates the presence of voltage on the equipment
outlet connections.
4
7-segment display
Allows the general welding machine parameters to be
displayed during start-up, settings, current and voltage
readings, while welding, and encoding of the alarms.
5
LCD display (3.5"/4.7")
Allows the general welding machine parameters to be
displayed during start-up, settings, current and voltage
readings, while welding, and encoding of the alarms.
Allows all the operations to be displayed instantaneously.
6
Main adjustment handle
Allows entry to set up, the selection and the setting of
the welding parameters.
7
Processes/functions
Let you select the various system functions (welding
process, welding mode, current pulse, graphic mode,
etc.).
8
Not used
9
Programs
Allows the storage and management of 64 welding
programs which can be personalised by the operator.
3.3 Starting Screen
When switched on, the generator performs a succession of
checks in order to guarantee the correct operation of the system
and of all the devices connected to it.
At this stage the gas test is also carried out to check the proper
connection to the gas supply system (system for automation and
robotics).
3.4 Main Screen
Allows the control of the system and of the welding process,
showing the main settings.
MMA
TIG DC
32
1
Measurements
During the welding operation, the real current and volt-
age measurements are shown on the LCD display.
1a Welding current
1b Welding voltage
2
Welding parameters
2a Welding parameters
Select the required parameter by pressing the encoder
button.
Adjust the value of the selected parameter by rotating
the encoder.
2b Parameter icon
2c Parameter value
2d Unit of measurement of the parameter
3
Functions
Allow the setting of the most important process func-
tions and welding methods.
3a
VRD Voltage Reduction Device
Shows that the no-load voltage of the equipment is
controlled.