Technical Data
Inverter Welder
Art. No
Degree of protection
Insulation class
Rated input voltage
(AC Current) U
1
Mains frequency
Protection, time delay
No-load voltage U
Idle state power
Efficiency of the
Welding Power Source
Load voltage U
2
Welding current I
Switch-on time X *
Regulated section
Welding current
Maximum rated
input current I
1max
Maximum effective
input current I
1eff
Material thickness
Dimensions L x W x H
Net/gross weight
This device consists of the following recyclable materials:
Sheet steel, Copper, Aluminum, ABS, PE
* The ratio of given duration time/the full-cycle time.
Note 1: This ratio shall be within 0~1, and can be indicated by percentage.
Switch-on time determined at 40°C using simulation
the safety measures stated in the service manual. Act
responsibly toward third parties.
In case of any doubts about connection and
operation refer please to our customer center
Specified Conditions Of Use
Welder in protective atmosphere for thermal connec-
tion of ferrous metals by melting edges and including
mixture
GIS 122
20122
IP 21S
H
230 V
50 Hz
16 A
60 V
0
17 W
83 %
22.2 V 22.8 V 24.8 V 22.5 V 23.3 V 25.6 V 22.9 V 23.7 V 26.4 V
54 A
70 A
2
100 % 60 %
10 - 120 A
22.0 A
9.9 A
1 - 5 mm
280 x 135 x 220 mm
3.1 kg / 5.1 kg
Read and understand the
operating instructions before
using the appliance. Abide by all
GIS 142
20123
IP 21S
H
230 V
50 Hz
16 A
60 V
17 W
83 %
120 A
63 A
81 A
140 A
20 %
100 % 60 %
20 %
10 - 140 A
26.0 A
11.7 A
1 - 7 mm
295 x 135 x 220 mm
3.4 kg / 5.4 kg
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.Please
note that our equipment has not been designed for
commercial, craft or industrial use. If the equipment is
used in commercial, craft or industrial operation or for
similar activities, we cannot assume any liability.
Ambient temperature -10 °C - +40 °C
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
GIS 162
20124
IP 21S
H
230 V
50 Hz
16 A
60 V
17 W
84 %
71 A
93 A
160 A
100 % 60 %
20 %
10 - 160 A
30.5 A
13.7 A
1 - 9 mm
295 x 135 x 220 mm
3.5 kg / 5.5 kg