Guardian Technologies H1175 Instrucciones De Uso Y Cuidado página 4

Llenado fácil por la parte superior humidificador ultrasónico
Idiomas disponibles

Idiomas disponibles

CLEANING (cont.)
ULTRASONIC DISK
1. Unplug unit.
2. Empty the tank by pouring all the water on the
left side (see arrow inside tank). Remove the
mist tube by rotating it counter clockwise.
3. Locate the ultrasonic disk on the
inside center of the base unit.
4. Use ONLY the enclosed cleaning brush
to gently clean disk and remove build up
and deposits.
Do not scrub or scrape the ultrasonic disk.
Ultrasonic Disk
Clean the disk with the brush only.
No other cleaning tool should
be used. BRUSH ONLY.
If scale becomes difficult to remove with brush:
1. Fill the tank with: mixture of 1 tap. white vinegar and 1 tap. water.
2. Let solution stand for 5 minutes.
3. With the vinegar in the tank, clean all interior surfaces with a soft cloth or brush to help remove scale.
4. Also check mist nozzle and mist tube in water tank. Clean as needed.
5. Rinse the tank thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
• Follow the Cleaning and Descaling instructions when the humidifier will be stored at
the end of the season.
• Dry the humidifier completely before storing. DO NOT store with water inside the
Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING
YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER
OR PERSONAL INJURY.
E-6
PROBLEM
Water vapor and humidity
are not produced.
Air blows but water vapor
is not produced.
Looking down
at the inside of
empty tank.
Humidity level is low.
The humidity has
a bad smell.
White dust is forming on
nearby furniture.
Unit has stopped working.
Water is accumulating
outside of unit or area
surrounding unit.
Increased noise level.
Red light below power dial.
TROUBLE SHOOTING GUIDE
SOLUTION
Power Plug: Unplug and then try again.
Power Failure: When the power is returned, try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6)
Excessive Water: Remove a certain amount of water from the tank.
Excessive Water in mist tube. Remove water from tank and mist
chamber and try again.
Detergent residue and/or oil ingredients from cosmetics, eta may be in
tank; wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6) If you use hard water, replace with softer water.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
(see pa. E-6)
The water in the unit is too cold: Replace with cool, but not cold water.
Damage on the ultrasonic disk: Contact Customer Service
Poor maintenance or dirty water: Clean the product thoroughly,
and fill it with fresh water. (see pa. E-5)
Hard water may deposit a certain amount of dust. Dust in the air also
settles because of added humidity in the room. Use distilled water if
this becomes a nuisance.
No or low water. Unplug unit and refill tank.
Saturation of humidity. Lower mist control setting.
Unit not level and water is accumulating. Unplug and place on level
surface. Point spray away from objects. Raise unit on a water-resistant
level surface 2-3 feet off of floor.
Unit must be placed on a flat, level, hard surface.
Make sure it is NOT placed on a soft or absorbent surface.
Indicates low water. Unplug and refill tank.
E-7
loading