CLEANING
1. Always unplug the unit before servicing in any way.
GENERAL CLEANING
2. Inside the base of the unit. Pour excess water out of the unit. Wash out the unit with fresh water using the
cleaning brush and a soft cloth as needed. Do not submerse the base of the unit into water, or allow
water to enter inside the dry air exhaust port of the unit.
3. Water tank. Empty water tank. Pull and remove mist spout out of the tank. Clean the mist tube with fresh
water and a light brush (bottle cleaning brush is recommended). Return mist spout after cleaning.
4. Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if needed. If you notice an
accumulation of water during usage, reduce humidity and dry outer surface with a cloth.
DESCALING
• Depending on usage and water type, cleaning to remove scale may be required weekly or every
other week to optimize unit performance.
• If you live in a hard water area, we recommend the use of distilled water for your humidifier. This will
help reduce the precipitation of minerals or 'white dust'.
• Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.
ULTRASONIC DISK
1. Unplug unit.
2. Remove the tank and empty all water from unit base and tank.
3. Locate the ultrasonic disk on the inside center of the base unit.
4. Use ONLY the enclosed cleaning brush to gently clean disk
and remove build up and deposits.
Do not scrub or scrape the ultrasonic disk.
If scale becomes difficult to remove with brush:
1. Fill the Base with: mixture of 1/4 cup white vinegar
and 1/4 cup water.
2. Let solution stand for 5 minutes.
3. With the vinegar in the Base, clean all interior surfaces
with a soft cloth or brush to help remove scale.
4. Also check mist nozzle and mist tube in water tank. Clean as needed.
5. Rinse the Base thoroughly with water to remove scale and vinegar solution.
END OF SEASON STORAGE
• Follow the Cleaning and Descaling instructions when the humidifier will be stored at the end of the season.
• Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
• Pack the unit in its original carton and store in a cool, dry location.
NOTE: IF YOU EXPERIENCE A PROBLEM DO NOT ATTEMPT TO OPEN THE MOTOR
HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE
TO THE HUMIDIFIER OR PERSONAL INJURY.
E-6
Ultrasonic
Disk
*Clean the disk with the
brush only. No other cleaning
tool should be used.
BRUSH ONLY.
TROUBLE SHOOTING GUIDE
PROBLEM
SOLUTION
Power Plug: Unplug and then try again.
Water vapor and humidity
are not produced.
Power Failure: When the power is returned, try again.
Tank Installation: Make sure the tank is correctly attached.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk
The desired humidity is lower than the current humidity in the room.
Check Humidistat settings.
Air blows but water vapor
Excessive Water: Remove a certain amount of water from the tank.
is not produced.
The desired humidity is lower than the current temperature:
Check Humidistat settings.
Detergent residue and/or oil ingredients from cosmetics, etc. may be in
tank; wash out tank and try again.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
If you use hard water, replace with softer water.
Humidity level is low.
The surface of the ultrasonic disk is dirty: Clean ultrasonic disk.
The water in the unit is too cold: Replace with cool, but not cold water.
Damage on the ultrasonic disk: Contact Customer Service
Poor maintenance or dirty water: Clean the product thoroughly,
The humidity has
and fill it with fresh water.
a bad smell.
Hard water may deposit a certain amount of dust. Dust in the air also
White dust is forming on
settles because of added humidity in the room. Use distilled water if
nearby furniture.
this becomes a nuisance.
Unit has stopped working
No or low water. Unplug unit and refill tank.
The desired humidity is lower than the current humidity in the room.
Check humidistat settings.
Water is accumulating outside
Saturation of humidity. Lower mist control setting.
of unit or area surrounding unit.
Unit not level and water is accumulating. Unplug and place on level
surface. Point spray away from objects. Raise unit on a water-resistant
level surface 2-3 feet off of floor.
Water dripping when refilling.
Water remaining on bottom of tank. Wipe tank or tilt to drain
before transporting.
Increased noise level.
Unit must be placed on a flat, level, hard surface. Make sure it is NOT
placed on a soft or absorbent surface.
Red light on power dial.
Indicates low water. Unplug the tank and refill tank.
Add a few more drops of oil to aroma pad.
Cannot smell aroma scent.
Replace aroma pad with a new one.