8.2. PERIODIC MAINTENANCE

Always use adequate spare parts in order to obtain a
proper performance of the product and avoid damage
and risks to machine and user. Spare parts should be
purchased at the official service dealer. The use of
non-official spare parts may cause risk of accident,
injury to the user and breakage of the machine.
Perform maintenance frequently as indicated in the
following table:
Operation
Check that there are no loose parts
Check the condition of hoses and gun
Check the oil level
Change the engine oil
Change oil from the pump
Clean the air filter
Check the spark plug

8.2.1. AIR FILTER

The dirt in the air cleaner will cause a reduction in the
performance of the machine. Check and clean this
element. If you notice damage or alterations to the
filter, replace it with a new one.
1. Remove the protective cap from the filter.
2. Remove the filter.
3. Clean the filter with soapy water.
4. Rinse the filter with clean water.
5. Dry the filter.
6. Once dry, moisten it with 2 drops of oil (if you wet
the filter with too much oil the machine cannot
start).
7. Install the filter on the machine.
8. Put on the protective cap.
Nota: El motor nunca debe funcionar sin el filtro
de aire instalado.