HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Operate by COOL mode with the highest temperature
set or FAN mode for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 8
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the "PREPARATION BEFORE OPERATION",
and follow the instructions.
S
PECIFICATIONS
Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R410A)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/
High/Med./Low/Silent)
Noise level
Outdoor
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
Page 4
Page 3
MSZ-SF25VE3(H)
MSZ-SF25VE3
MUZ-SF25VE(H)
Cooling
Heating
kW
2.5
3.2
kW
0.60
0.78
kg
kg
31
kg
0.70
MPa
MPa
42/36/30/
45/39/34/
dB(A)
24/19
24/19
dB(A)
47
48
Outdoor
MUZ-SF25/35/42/50VE
MUZ-SF25/35/42/50VEH
46°C DB
46°C DB
-10°C DB
-10°C DB
24°C DB
24°C DB
18°C WB
18°C WB
-15°C DB
-20°C DB
-16°C WB
-21°C WB
I
NSTALLATION PLACE AND
ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as hot spring, sewage, waste water.
• Where oil is splashed or where the area is fi lled with oily smoke (such as
cooking areas and factories, in which the properties of plastic could be
changed and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit bothers the house
next door.
• The mounting height of indoor unit 1.8 m to 2.3 m is recommended. If it is
impossible, please consult your dealer.
• Do not operate the air conditioner during interior construction and fi nishing
work, or while waxing the fl oor. Before operating the air conditioner, ven-
tilate the room well after such work is performed. Otherwise, it may cause
volatile elements to adhere inside the air conditioner, resulting in water
leakage or scattering of dew.
Inverter-type
To prevent the effects
fl uorescent lamp
of a fl uorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent
the picture
distortion or
1 m
the noise.
or more
1 m
or
Cordless
more
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MSZ-SF35VE3(H)
MSZ-SF42VE3(H)
MSZ-SF35VE3
MSZ-SF42VE3
MUZ-SF35VE(H)
MUZ-SF42VE(H)
Cooling
Heating
Cooling
~ /N, 230 V, 50 Hz
3.5
4.0
4.2
1.08
1.03
1.34
10
31
0.80
IP 20
IP 24
1.64
4.15
42/36/30/
46/40/34/
42/38/34/
24/19
24/19
31/26
49
50
50
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
DB: Dry Bulb
WB: Wet Bulb
The installation location of the outdoor
unit should be at least 3 m away from
the antennas for TV sets, radios, etc. In
areas where the reception is weak, pro-
vide greater space between the outdoor
unit and the antenna of the affected
device if operation of the air conditioner
interferes with radio or TV reception.
For the optimum ef-
fi ciency and to extend
wall, etc.
the life time of using,
the outdoor unit
should be installed in
a well-ventilated dry
place.
100 mm or
more
(SF25, 35, 42/SF50)
200/500 mm or more
TV
3 m or more
MSZ-SF50VE3(H)
MSZ-SF50VE3
MUZ-SF50VE(H)
Heating
Cooling
Heating
5.4
5.0
5.8
1.58
1.66
1.70
35
55
1.15
1.55
47/42/36/
45/40/36/
49/43/38/
31/26
33/28
33/28
51
52
52