9.2 AC VOLTAGE
range
4 V
40 V
400 V
500 V
Average sensing, calibrated to rms of sine wave
Frequency range: 40-500 Hz
Overload protection: 500 V DC or AC rms
Impedance: 10 MΩ
9.3 DC CURRENT
range
400 µA
4000 µA
40 mA
400 mA
4 A
10 A
Overload protection: F0.5 A/500 V fuse, F10 A/500 V fuse
10 A up to 10 seconds
9.4 AC CURRENT
range
400 µA
4000 µA
40 mA
400 mA
4 A
10 A
V. 01 – 06/04/2017
Do not measure circuits that may contain voltages
> 500 VDC or > 500 VAC
resolution
1 mV
10 mV
100 mV
1 V
Do not measure circuits that may contain voltages
> 500 VDC or > 500 VAC
resolution
0.1 µA
1 µA
10 µA
100 µA
1 mA
10 mA
Do not measure circuits that may contain voltages
> 500 VDC or > 500 VAC
resolution
0.1 µA
1 µA
10 µA
100 µA
1 mA
10 mA
DVM855
accuracy
± (0.8 % rdg + 3 digits)
± (1.2 % rdg + 3 digits)
accuracy
± (1.2 % rdg + 2 digits)
± (2.0 % rdg + 3 digits)
accuracy
± (1.5 % rdg + 3 digits)
± (2.5 % rdg + 5 digits)