Kitchen Aid 720-0891C LP Instrucciones De Instalación Y Manual De Uso Y Cuidado página 24

Idiomas disponibles

Idiomas disponibles

720-0891C/D/G/H (LP), 730-0891C/D/G/H (NG) orifice sizes
Components
Main Burner
IMPORTANT: The burner valves in this grill have a specific BTU rating. This means that the amount of gas coming from
each orifice is measured to create the BTU. The holes in the orifices themselves are drilled to different sizes so as to
allow the proper amount of gas to flow through them. Please note the chart above as an easy reference for the various
orifice opening sizes for the valves in the grill.
WARNING
This conversion kit shall be installed
by a qualified service agency in
accordance with the manufacturer's
instructions and all applicable codes
and requirements of the authority
having jurisdiction. If the information in
these instructions is not followed
exactly, a fire, explosion or production
of carbon monoxide may result
causing property damage, personal
injury or loss of life. The qualified
service agency is responsible for the
proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specified in
the manufacturer's instructions
supplied with the kit.
GAS CONVERSIONS
Liquid Propane (LP)
Orifice Size
1.05 mm
24
BTU/HR
Orifice Size
13,000
1.75 mm
Tools and Parts for Gas Conversion
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
Natural gas orifices
Parts needed
Natural gas conversion kit Part Number 710-0003. See
"Assistance" section to order. The conversion kit includes:
(NOT INCLUDED WITH APPLIANCE)
Natural gas regulator 4" W.C. (marked "Natural Gas
Regulator")
10 ft (3.0 m) Natural gas hose with quick connector
5.9" (150 mm) Natural gas regulator hose
6 mm nut driver
6 mm wrench
Hex key
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with conversion, shut off the gas
supply to the grill.
Natural Gas (NG)
BTU/HR
13,000
loading