PNI C120 Manual De Usuario página 10

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
The charger does not
F05
enter "float" state
within 24 hours.
F06
Reversed polarity.
The charging voltage
F07
is too high during the
alternator test.
The charging voltage
F08
is too low during the
alternator test.
Technical specifications
Input voltage
Charging voltage
Charging current
Types of batteries
Dimensions
Weight
Operating temperature
User manual
The charging current
is too low.
A load is connected
to the battery.
The battery is
defective.
The charger's clips
were connected
incorrectly.
Poor functioning
regulator.
Belt may be loose.
Poor functioning
alternator.
200-240VAC, 50Hz
14.4V (winter 14.6V) - standard
vehicles
14.6V (winter 14.8V) - START/
STOP (AGM) vehicles
Up to 12A
Lead acid, Gel, Calcium, AGM,
EFB 25-300Ah (charging)
195 x 138 x 78 mm
1.51 kg
-26°C ~ +80°C
Disconnect the
charger from the
AC mains, restart
and select a higher
charging current.
Remove the load
from the battery.
Replace the battery.
Reconnect the
chargers clips
correctly.
Check the regulator.
Check the belt and
the alternator.
10