Error codes
Code Details
The battery voltage
is below 12V, after
charging for 300
min.
If after 20 hours
F01
(five times in
reconditioning
mode), due to a
faulty battery, the
battery does not
enter the "float"
stage.
The battery voltage
F02
is too high.
Actual charging rate
F03
exceeds the set
charge rate.
The charger
F04
temperature is too
high.
9
Reason
The battery is
defective or a load
is connected to the
battery.
Battery is
sulfated beyond
reconditioning.
Battery rated above.
Error during
charging process or
interference from
another device.
The charger is
located in a location
with too high a
temperature and
without ventilation.
Action
Replace the battery.
Disconnect the load
from the battery.
Replace the battery.
Check the battery
rating.
Disconnect the
charger from the AC
mains and restart. If
the problem persists,
the rectifier is
defective.
Disconnect devices
that may cause
interference.
Select a lower
charging current to
continue charging
or allow the charger
to cool for 30 min.
Leave at least 10 cm
around the charger
for its ventilation.