OVER-VOLTAGE PROTECTION
Guards against charging errors where the charger is programmed to charge in a different voltage than the detected
voltage of the battery. When this safeguard is engaged, the ERROR LED will slowly flash (2.0s-ON/2.0s-OFF). To reset
the charger, disconnect from AC outlet, reset the vehicle connections and reconnect to the AC outlet.
I
For Conventional and Maintenance Free flooded (wet) batteries, the ideal Battery Type selection is "STD".
For batteries identified as AGM construction, the ideal Battery Type selection is "AGM".
For batteries identified as LiFe construction, the ideal Battery Type selection is "LiFeP04".
For most Spiral Wound batteries, the best Battery Type selection is "AGM".
For batteries identified as Deep Cycle, determine the construction of the battery. Is it a wet cell battery or another type of
construction? This will determine the proper Battery Type selection.
For batteries identified as Marine, determine the construction of the battery. Is it a wet cell battery or another type of
construction? This will determine the proper Battery Type selection.
J
CAUTION – Make sure charger is unplugged from
electrical outlet before performing any maintenance.
A minimum amount of care can keep your battery charger
working and looking good for years.
1. Clean the clamps after each use. Wipe off any battery
fluid that may have come in contact with the clamps
to prevent corrosion. Battery fluid may be neutralized
with a solution of water and baking soda.
CHOOSING THE BATTERY TYPE
CHARGER CARE & MAINTENANCE
2. If needed, the case may be wiped clean with a soft
cloth.
There are no user-serviceable parts inside.
For information concerning use, applications, or service,
call Technical Service at 800.328.2921.