SICK WI130 Manual De Instrucciones página 60

Ocultar thumbs Ver también para WI130:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
OPERATING INSTRUCTIONS
9
Maintenance
en
10
Technical data
10.1
Technical specifications
The "Technical Data" section contains only an extract of the technical data of the sensor.
The complete technical data can be found on the homepage
Features
Table 27: Technical data
WI130T
Adjusted sensor head
Supply voltage
Power consumption
Response time
Digital output
Display
Time delay
Switch-on/off delay
Analog output
Input/output entry
60
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
Never use sharp objects for cleaning.
Clean the optical surfaces at regular intervals and, in the event of contamina‐
b
tion, with a lint-free lens cloth (part number 4003353) and plastic cleaner (part
number 5600006). The cleaning interval essentially depends on the ambient
conditions.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
Standard type (1x Out)
Charging current: ≤ 100 mA, residual voltage: ≤ 1.8 V
External entry
(Single Value Teach-in, input synchroni‐
zation, counter reset)
www.sick.com
under the part number of the sensor.
Advanced type (2x Out)
W130 product family
DC 12...24 V ± 10 %
≤ 45 mA / 24 V
60 μs/500 μs/2 ms (fast/standard/far)
NPN / PNP open collector
7-segment display
ON / OFF delay 0 ... 9 s
1 ms ... 9 s
(Single Value Teach-in, input synchroniza‐
(2x Out output + alarm output)
4 ... 20 mA
External entry
tion, counter reset)
Output setting
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
loading