6.9
Manual adjustment
6.10
Function configuration
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
Press the UP/DOWN switch during operation and the threshold flashes. Configuration is
now possible. Adjustment using the UP/DOWN switch.
The upper/lower limit values can be set individually during a Zone teach-in.
Normal
↓
3 0 0 3 5 0
Automatically reverts to the
normal display 5 seconds
after completing the configu‐
ration (no operation).
NOTE
The display also reverts if there is a pause of 5 seconds during configuration.
Notes on function configuration
•
Incorrect or harmful settings are automatically deleted. This is not a malfunction.
•
Some functions have not been integrated into the WI130T-P/N340 or cannot be
configured.
•
Press the operating button for approx. 0.3 s if not specified otherwise.
•
Analog output is not possible when the response time is set to Fast. Output is only
available for Long or Stnd (Standard).
•
The secondary display flashes if the selection is available.
•
The display shows "U" in the counter function when counting down and "d" when
counting up.
•
For all functions other than operating mode and time type configuration, both
1x Out and 2x Out are changed when the setting for the respective function is
changed.
•
The "Universal configuration" described in 5.8 to 5.10 is only required if the
evaluation unit is connected to another unit via the bus connector.
•
The functions or indications may vary in some cases.
Function configuration
Press the mode switch.
↓
1. Operating mode configuration
OPERATING INSTRUCTIONS
During a Zone teach-in
Setting the upper limit (far)
↓
F A r
1 0 0
3 0
Automatically reverts to the normal display 5 seconds after
completing the configuration(no operation).
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
Setting the lower limit (near)
↓
n E A r
1 0 0
1 5 0
en
49