SICK WI130 Manual De Instrucciones página 51

Ocultar thumbs Ver también para WI130:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice
Table 6: Time configuration
Select from various time delay options
t I E r o f f
TOP
Time period of 1-9000 (1 ms–9 s) can be selected
for configuration. The display then reverts to the Time delay
top menu.
NOTE
Time delay can be set individually for 1x Out and 2x Out.
NOTE
It is not possible to use ON-Delay and OFF-Delay at the same
time in the same channel.
4. Configuring the sensitivity correction
Table 7: Configuring the sensitivity correction
Scales the sensitivity range.
t u r n o n
Configuration by status is shown in the bar graph. The display
then reverts to the Sensitivity correction top menu.
TOP
5. Detailed settings (expert mode)
Table 8: Configuring the sensitivity correction
Changes to detailed configuration.
E P r t
table 10
TOP
6. Initialization
select and adjust
o F F
o F d y
o n d y
S H o t
is for time period change, is for digital change and is
o F d y 0 0 0 1
o n
o F F
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
OPERATING INSTRUCTIONS
. OFF reverts to initial display.
No time delay activated
OFF-Delay
ON-Delay
One-Shot
Switch on the sensitivity
correction.
Switch off the sensitivity
correction.
en
51