SICK WI130 Manual De Instrucciones página 46

Ocultar thumbs Ver también para WI130:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
OPERATING INSTRUCTIONS
en
6.6
Zone teach-in
46
O P E R A T I N G I N S T R U C T I O N S | Evaluation unit WI130
Select Auto teach-in.
A u t o S t r t
Start: Press the teach-in button.
A u t o S t r t
End: Press the teach-in button.
A u t o S t o P
A u t o g o o d
Pin on RUN.
SET
RUN
The threshold flashes and the display
reverts to the initial setting.
Pin on SET.
SET
RUN
Select Zone teach-in.
Z o n E
Press the teach-in button.
Z o n E
WT, WL, WSE start and end: Automatic con‐
figuration during the running process
Sets the threshold to the average of the
maximum and minimum value that was
detected between Auto Start and Auto Stop.
Proximity sensor (WT): Adjust with object
present.
8020148.1HRJ/2023-02-08 | SICK
Subject to change without notice