Stored welding spots selection configurations: the selection of the stored welding spots is directly defined by this combination of
digital inputs.
CN3-8
Wire 9
CN3-16 Wire 8
CN11-1 Wire 52
The combination of these first 3 digital processes is summarised in the following table:
CN11-1 (Wire 52)
CN3-8 (Wire 9)
0
1
0
1
0
0
0
0
CN3-15
Wire 7
Wire 6
CN3-14
Wire 5
CN3-13
Wire 4
CN3-12
Wire 3
CN3-11
Wire 2
CN3-10
Wire 1
CN3-9
SYNERGY/MEMORY: command signal for selecting synergetic curves or retrieving stored weld-
ing spots.
1 = synergetic curve retrieval enabled
0 = retrieval of stored welding spots enabled
NOT USED: leave the signal on 1.
NOT USED: leave the signal on 0.
CN3-16 (Wire 8)
0
Retrieval of synergetic curves in Mig Short Spray Arc enabled.
1
Retrieval of synergetic curves in Pulsed MIG enabled.
1
Retrieval of stored welding spots enabled.
0
Not used.
CODING: the combination of these digital signals makes it possible to deter-
mine the synergetic curve or the required welding spot.