R290 SAFETY
Additional warnings for appliances with R290 refrigerant gas.
Read the instruction carefully before using the appliance.
R290 refrigerant gas complies with EN60335-2-40 .
This appliance contains a certain number of grams (see rating
label at the back of the unit) of R290 refrigerant gas. The
maximum refrigerant charge amount is not greater than R290
0.304kg based on EN60335-2-40.
When defrosting or cleaning, do not use any method other than
those recommended by the manufacturer.
Do not place the appliance in a room with continuous sources
of ignition (e.g. open flame, operating gas appliance or working
electrical heater).
Do not pierce and do not burn.
Do not perforate any part of the refrigerant circuit.
Refrigerant gas may be odorless.
The appliance must be installed, used and stored in an area that
is greater than R290 gas: 12 m².
The minimum rated airflow is 85 m³/h.
Accumulation of possible refrigerant leaks in an unventilated
room could lead to fire or explosion should the refrigerant
come in contact with electric heaters, stoves or other sources of
ignition.
The appliance must be stored in a way to prevent mechanical
damage and in a well-vented area.
Only individuals authorized by an accredited organization
certifying their competence to handle refrigerants in compliance
with industry legislation should work on the refrigerant circuit.
Servicing shall be performed only as recommended by
the manufacturer. Maintenance should only be done by
professionals.
All working procedure that affects safety means shall only be
carried by competent persons.
Repair must be performed based on the recommendations from the manufacturer.
Maintenance and repair that requires the assistance of other qualified personnel must be
performed under the supervision of specialists in the use of flammable refrigerants.
EN