Selco RI2000 Instrucciones De Uso página 48

Ocultar thumbs Ver también para RI2000:
Idiomas disponibles
  • ES

Idiomas disponibles

5 CONNECTORS
5.1 Connector CN1/J1 (12-pole)
CN1-1
AI3: ANALOG input 3 (-)
CN1-6
LINE B (RS485
CN1-7
AI3: ANALOG input 3 (+)
CN1-11
LINE A (RS485)
CN1-12
GND (RS485)
CN1-3
RS232 (RX)
CN1-9
RS232 (TX)
CN1-4
GND (RS232)
5.2 Connector CN2/J2 (4-pole)
CN2-1
+24V
CN2-2
Ground (PE)
CN2-3
Ground
CN2-4
Ground
5.3 Connector CN3 (16-pole)
CN3-1
START ARC input
0V = arc OFF
24V = arc ON
48
CN3-2
CN3-3
CN3-4
J1-1
Wire 25
J1-6
Wire 24
CN3-5
J1-7
Wire 21
J1-11
Wire 22
CN3-6
J1-12
Wire 23
J1-3
-
J1-9
-
CN3-7
J1-4
-
CN3-8
CN3-9
CN3-10
CN3-11
CN3-12
CN3-13
J2-1
Wire 20
CN3-14
J2-2 Yellow green wire
CN3-15
J2-3
Wire 19
CN3-16
J2-4
Wire 18
J3-1
Wire 16
Input for PIECE SEARCH
0V = test inactive
24V = test active
WIRE BACK input:
0V = wire back inactive
24V = wire back active
GAS TEST input
0V = test inactive
24V = test active
AIR TEST input
0V = no air flow
24V = air flow
WIRE EXTENSION input:
0V = wire not extended
24V = wire extended
ALARMS RESET input
0V = no reset operation
24V = alarms reset
PROCESS input
Coding input
Coding input
Coding input
Coding input
Coding input
Coding input
Coding input
PROCESS input
J3-2
Wire 15
J3-3
Wire 14
J3-4
Wire 13
J3-5
Wire 12
J3-6
Wire 11
J3-7
Wire 10
J3-8
Wire 9
J3-9
Wire 1
J3-10
Wire 2
J3-11
Wire 3
J3-12
Wire 4
J3-13
Wire 5
J3-14
Wire 6
J3-15
Wire 7
J3-16
Wire 8
loading