Synergetic curve selection configurations: the selection of synergetic curves is directly defined by this combination of digital
inputs.
CN3-8
Wire 9
CN3-16
Wire 8
CN11-1
Wire 52
CN11-4
Wire 55
Standard configuration
0V = 0 Input opened or not connected (low state)
24V = 1 Input closed or powered (high state)
CN11-4
CN11-1
Wire 55
Wire 52
0
0
0
0
0
0
0
0
CN3-15
Wire 7
CN3-14
Wire 6
CN3-13
Wire 5
CN3-12
Wire 4
CN3-11
Wire 3
CN3-10
Wire 2
CN3-9
Wire 1
Consult the section "Set-up parameter 400" (Genesis ... repair manual)
The combination of these digital processes is summarised in the following table:
CN3-8
CN3-16
Wire 9
Wire 8
Retrieval of synergetic curves in MIG/MAG Short Spray Arc enabled.
1
0
Retrieval of synergetic curves in Pulsed MIG/MAG enabled.
1
1
Retrieval of stored welding spots enabled (JOB).
0
1
Not used.
0
0
CODING: the combination of these digital signals makes it possible to determine the synergetic curve
or the required welding spot.
Inverted configuration
0V = 1 Input opened or not connected (low state)
24V = 0 Input closed or powered (high state)