3.9 Digital outputs (connector CN7, CN8, CN11)
Use the following pins as a reference for the ground connections: pins CN9-4, CN9-5, CN9-11, CN9-12 (see paragraph 3.2).
CN7-1
Wire 49
(Imax = 100mA)
CN7-2
Wire 50
(Imax = 100mA)
CN7-3
Wire 51
(Imax = 100mA)
CN7-4
Wire 48
(Imax = 100mA)
CN7-5
Wire 47
(Imax = 100mA)
CN7-6
Wire 46
(Imax = 100mA)
CN8-1
Wire 41
(Imax = 100mA)
CN8-6
Wire 40
(Imax = 100mA)
CN11-3
Wire 54
(Imax = 100mA)
CN11-6
Wire 57
(Imax = 100mA)
PROGRAMMABLE PARAMETERS:
GAS CYCLE :
SAFETY LIMIT WARNING :
SAFETY LIMIT ALARM :
WELDING TOOL READY: this signal confirms that the welding tool is ready for use (none of the
system's alarms are active).
0V = system in alarm status
24V = welding tool ready for use
GAS PRESENCE: signal confirming gas flow.
0V = "no gas" alarm
24V = gas present
WATER PRESENCE: signal confirming water flow.
0V = water present
24V = "no water" alarm
SAFETY LIMITS: signal confirming that no alarm is active.
0V = safety limits alarm active
24V = no active alarm
ANTISHOCK ALARM (I-CAT)
0V = antishock alarm inactive
24V = antishock alarm active
PIECE PRESENCE: a signal confirming that the piece was touched during the touch operating mode.
0V = piece not touched
24V = piece touched
ARC ON: signal confirming that the electrical arc has been powered up.
0V = arc OFF
24V = arc ON
GLUED WIRE ALARM: a signal confirming that the wire was glued to the piece at end of welding.
0V = wire not glued
24V = wire glued
PROGRAMMABLE DIGITAL OUTPUT 1 (DO1): the parameter for this digital output can be selected
and programmed by control panel.
Default : not programmed
0V = digital output inactive
24V = digital output active
PROGRAMMABLE DIGITAL OUTPUT 2 (DO2): the parameter for this digital output can be selected
and programmed by control panel.
Default : not programmed
0V = digital output inactive
24V = digital output active
confirmation signal of gas cycle active.
0V = gas cycle inactive
24V= gas cycle active
confirmation signal of safety limit no warning active.
0V= safety limit warning active
24V = safety limit warning inactive
confirmation signal of no alarms.
0V = safety limit alarm active
24V = safety limit alarm inactive
CN7-1 (49) WELDING TOOL READY
CN7-2 (50) GAS PRESENCE
CN7-3 (51) WATER PRESENCE
CN7-4 (48) SAFETY LIMITS ALARMS
CN7-5 (47) ANTISHOCK ALARM
CN7-6 (46) PIECE PRESENCE
CN8-1 (41) ARC ON
CN8-6 (40) GLUED WIRE ALARM
CN11-3 (54) PROG. DIG. OUTPUT 1
CN11-6 (57) PROG. DIG. OUTPUT 2
CN9-4/5/12
45