1.
Insert the high pressure nozzle onto the
spray lance.
Install union nut and hand-tighten it
(EASY!Lock).
Join the spray lance with the trigger gun
and tighten until hand-tight
(EASY!Lock).
Join the high-pressure hose with trigger
gun and high-pressure connection of
the appliance and tighten until hand-
tight (EASY!Lock).
Hook the snap hook of the carrying belt
into the eyelets on the carrying handle
(picture see cover page).
WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
Electrical connection
DANGER
Danger of injury by electric shock.
– It is imperative to connect the appliance
to the electric mains by means of a plug.
It is forbidden to permanently connect
the appliance to the power supply. The
plug serves for the disconnection from
the mains.
– Use an extension cable with protective
earth conductor (protection class 1) and
an adequate cross section (see "Tech-
nical data") und fully uncoil it from the
cable drum.
For connection values, see type plate/tech-
nical data.
12
2.
Start up
Unwind the mains cable and place it on
the floor.
Insert the mains plug into a socket.
Water connection
Connection to the water supply
WARNING
Observe regulations of water supplier.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to the
water supply, never directly to the appliance!
For connection values refer to technical
specifications.
Connect the supply hose (min. length 7.5
m, minimum diameter 1/2") to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note:
The supply hose is not included.
Open the water supply.
Drawing in water from open reservoirs
Screw the suction hose with filter (optional
accessory) to the water connection.
Appliance ventilation:
Unscrew the nozzle from the spray lance.
Switch on the appliance and let it run
until the water exiting is bubble-free.
Let the appliance run for 10 seconds –
then switch off the appliance switch.
Repeat the procedure several times.
Switch off the appliance and fit the noz-
zle again.
DANGER
Risk of explosion!
Do not spray flammable liquids.
If the appliance is used in hazardous areas
(e.g. filling stations) the corresponding
safety regulations must be observed.
– 3
EN
Operation