OLIGO CHECK-IN Instrucciones De Montaje página 14

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Picture 6:
1.
2.
Typ A
4.
MOUNTING THE CABLE FEED
The cable feed can be supplied with reducible leads in lengths of 0.6 m or 1.6 m.
Please note that the cable feeds are not load bearing components. A static load is not permitted.
Picture 7:
1.
Fit the attachment plate to the ceiling
with the dowels and screws provided.
2.
If necessary, loosen the strain reliever for the lead,
slide back and shorten the cable.
Fit the connector lead to the mains connector provided.
3.
Attach the box to the plate with both lateral screws.
4.
Remove screw cap, fi t the current track in the holder
and re-tighten the screw cap.
INSTALLATION OF THE WALL END FEED
The wall end feed is only suitable for gallery tracks and is designed as a load bearing component. In a similar
way to the wall track carriers, a static load (Page 4) is permitted.
Picture 8:
1.
Push the cover over the fi tted current track.
2.
Use the plug and screw supplied to secure the wall fastening
10mm next to the track end centering to the track longitudinal
axis.
3.
Push the connector section onto the track , fasten using the
side grub screw and connect the mains lead.
Securely tighten front grub screw to the connector section.
4.
Push cover over the feed and fi x with the cylinder head hex
agonal screw and toothed lock washer.
INSTALLATION OF THE CABLE END FEED
The cable end feed is provided with a 5,000 mm long lead which can be shortened.
Please note that the cable feeds are not load bearing components. A static load is not permitted.
14
1.
Fit the attachment plate to the ceiling
L
with the dowels and screws provided.
2.
Fit the mains lead.
N
3.
Attach the box to the plate with
both lateral screws.
3.
4.
Type A: Remove screw cap, fi t the current
track in the holder and re-tighten the
screw cap.
Type B: Ref. Picture 3
4.
1.
2.
4.
1.
2.
3.
Typ B
L
N
3.