Picture 1:
Type A Carrier System:
1.
1.
Fix ceiling fl ange to the ceiling with dowels and screws.
Take care regarding accurate bore separation for this!
2.
2.
Screw rod holder into the ceiling fl ange.
3.
After releasing the lateral set screw the rod can be adjusted in height and
alignment.
4.
Then securely re-tighten the lateral set screw.
The Type A carrier system can be optionally positioned along the longitudinal
4.
3.
axis.
NOTE:
A fl exible steel cable (1.5 m, reducible) can be delivered for suspensions
longer than 525 mm.
Type B Carrier System:
1.
Ceiling fl ange-assembly as for type A carrier system
The carrier itself is only used with the mounted track (see next section).
2.
The type B carrier system can be supplied in 3 versions:
A
for static suspension (fi tting point always on the track seam) and
simultaneously for electrical connection
B
for static suspension (fi tting point always on the track seam) and
simultaneously for electrical isolation of circuits.
C
for static suspension only and is optionally positionable along the
longitudinal axis.
NOTE: A fl exible steel cable (1.5 m, reducible) can be delivered for suspensions
Wall Track Carrier
ASSEMBLY OF WALL TRACK CARRIER
For type A carrier systems the track can be simply fi tted into the pre-assembled track carrier.
For type B carrier systems the track together with the track carriers is pre-assembled on the fl oor in sections and then
fi tted into the wall fl ange.
4.
3.
1.
2.
max. 1500 mm
longer than 525 mm.
Type A Carrier System:
1.
Fix wall track carriers to the wall as shown on the
left. In doing this take care regarding an accurate
distance between bores (max. 1500 mm)!
2.
Fit current tracks into the wall track carriers from
bove.
Type B Carrier System
1.
Pre-assemble current tracks on the fl oor as for
connector (page 12)
2.
Attach wall track carrier fi xing fl ange to the wall
as shown on the right. In doing this take care
regarding an accurate distance between bores
(max. 1500 mm)!
3.
Place the wall track carrier with the track on the
fl ange and fi x with the locking screw. Tighten the
rear set screw securely (see page 12 "Connector-
Technology").
GB
Picture 1a:
Optional
Cover
Plate
3.
1.
2.
11