Section 4: Opecation
RECEPTACLES
CAUTION
m
NEVER attempt to power a device requiring more amperage
than generator
or receptacle can supply.
DO NOT overload the generator: See "Don't Overload
_ener_tor_'
12Volt
DC,
l0 Amp
Receptacle
This receptacie
allows you to recharge
a i2Voit
automotive
or udiity styie storage
battery
with the battery
charge
cabies provided
(Figure
i2).
This
receptacie
can not
recharge
6Voit
batteries
and
can
not
be used
to
crank
an engine
having
a discharged
battery.
See the
section
"Charging
a Battery"
(page
i0) before
attempting
to recharge
a battery.
1:20 Volt AC, 20 Amp,
Duplex
Each dupiex receptacie
(Figure
[ 3) is protected
against
overioad
by a push-to-reset
circuit
breaker.
Use each receptacie
to operate
i 20VoHtAC,
singie-phase,
60 Hz electricai
ioads requiring
up to 2,400 watts
(2.4 kW)
at 20 Amps of current.
Use cord sets that are rated
for
i 25 Voit AC ioads at 20 Amps (or greater).
1201240 Volt AC, 30 Amp,
Locking
Use a NEHA LH4-30 piug with this receptacie.
Connect
a
4-wire
cord set rated
for 250VoHtAC
ioads at 30 Amps (or
greater)
(Figure
i4).You can use the same 4-wire
cord if
you pian to run a i20Voit
ioad.
4°Wire
Cord
Set
(Neutral)
Y (Hot)
_
X (Hot)
NENA
L I
4-30
/-7 L7 Ground (Green)
This receptacle powers 120/240VoltAC,
60 Hz_single
phase loads requiring
up to 7,200 watts
of power
(7.2 kW)
at 30 Amps for i20Voits
or 240Volts.The
oudet
is
protected
by a rocker
switch circuit breaker.