120 VoJt, 20 Amp Locking Type
Receptacle
Usea NEMA L5-20plugwiththisreceptacle. Connect
a 3-wirecordsetratedfor 125VoltACloadsat
20Ampstothe plug.
3-Wire CordSet
NEMA L5-20
Neutral
120V
Hot
Ground (Green)
Use this receptacle to operate 120 VoJt AC, 60 Hz,
singJe phase loads requiring up to 2,400 watts
(2.4 kW) of power at 20 Amps. The outlet is protected
by a 20 Amp push-to-reset
circuit breaker.
120 Volt AC, 20 Amp,
Duplex
Receptacle
Each receptacle is protected against overload by a
20 Amp push-to-reset
circuit breaker.
Use each receptacle to operate 120 Volt AC,
single-phase,
60 Hz electrical loads requiring up to
2,400 watts (2.4 kW) at 20 Amps of current. Use cord
sets that are rated for 125 Volt AC loads at 20 Amps
(or greater).
12 Volt DO, 10 Amp Receptacle
This receptacle allows you to recharge a 12 Volt
automotive or utility style storage battery with the
battery charge cables provided.
This receptacle can not recharge 6 Volt batteries and
can not be used to crank an engine having a
discharged battery. See the section "Charging a
Battery" (page 11 ) before attempting to recharge a
battery.