Connection of pipelines
The dimension of multifunction
•
valve and the inlet /outlet pipe is
½"BSP.
•
Connection of multifunction valve:
install the multifunction valve with the
heater on the inlet of the water
•
heater.
In order to avoid leakage when
connecting the pipelines, the rubber
seal gaskets provided with the heater
must be added at the end of the
threads. Ensure leak proof joints.
•
The discharge pipe connected to the
pressure relief device must be kept
open to the atmosphere and be
installed in a frost-free environment
with a continuous downward slope.
Multi outlet connection
•
lf the users want to install a multi-way supply system, refer to the method
shown in Fig.4 for connection of the pipelines.
Joint
Hot water
outlet
5
o
ne-way safety valve
Pressure release hole
Joint screw for
cold water inlet
One-way safety valve
Water inlet valve
Cold water supply
( Fig. 3 )
( Fig. 4 )