7 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
Power supply (@PCC) Zmax
Slow blow line fuse
Communication bus
Maximum input power (KVA)
Maximum input power (Kw)
Power factor PF
Efficiency (µ)
Cosϕ
Max. input current I1max
Effective current I1eff
Duty factor (40°C)
(x=30%)
(x=60%)
(x=100%)
Adjustment range I2
Open circuit voltage Uo
Peak voltage Vp
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Manufacturing Standards
Power supply cable
Length of power supply cable
*
This equipment complies with EN/IEC 61000-3-12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
GENESIS 1500 TLH
1x230Vac ±15%
8mΩ *
16A
ANALOG
6.6kVA
4.6kW
0.70
87%
0.99
28.7A
15.7A
150A
125A
110A
5-150A
85Vdc
10.6kV
IP23S
H
260x115x250 mm
3.9 kg.
EN 60974-1/EN 60974-3/EN 60974-10
3x1.5 mm2
2 m
33