�
Safety Notes
� Gloves should be worn during installation to prevent
crushing and cutting injuries.
� The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 72842XXX, 72845XXX: The mixer can not used
together with a continuous flow water heater.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 39)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- connection hoses not completely
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 33)
English
Maintenance (see page 48)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions (see page 40)
Flow diagram (see page 40)
Spare parts (see page 45)
XXX = Colors
000 = Chrome Plated
670 = Matt Black
800 = Stainless Steel Optic
Special accessories (order as an extra)
Adapter (G⅜ / G½)
#93395000 (see page 45 / 47)
Cleaning (see page 43)
Operation (see page 44)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate (see page 48)
Remedy
- Exchange cartridge
- Exchange cartridge
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter