CONFIGURATION LOCK-OUT
Lock-out menu
In order to prevent accidental or indesirable modifications of instrument parameters, a selective or total
configuration lock-out is available. By default the unit is delivered unlocked, giving access to all programming
levels. Once in this menu, the first option will be to choose between lock-out level setting ("LiSt") or security
access code changing ("CHAn").
LiSt
tLoC
no
yES
SEt1
nO
yES
SEt2
nO
yES
InP
nO
yES
dSP
nO
yES
SERIE KOSMOS
If "LiSt" option is selected, display will show momentarily
"tLoc". Total configuration lock-out is activated by
selecting "yES", then routine directly jumps to RESET
CHAn
function and SHIFT key for MAX/MIN function lock-out
configuration before the unit goes back to RUN mode.
When total lock-out is set, no data can be entered
or modified, although it will still be possible to visualize
0000
all programmed parameters. Under these conditions when
entering main menu, initial indication will be "dAtA"
instead of "Pro".
On the other hand, when "no" option is selected, routine
move on to next step to configure a partial lock-out.
When a partial lock-out is set, only non-locked data
can be entered or modified. Under these conditions
when entering main menu, initial indication will be "Pro".
The following configuration access can be locked-out:
• Setpoint 1 configuration (SEt1)
• Setpoint 2 configuration (SEt2)
• Input configuration (InP)
• Display configuration (dSP)
• RESET function configuration (rSt)
• SHIFT key configuration for MAX/MIN function (MAH)
In each case lock-out is activated by selecting "yES" option and
deactivated by selecting "no".
Setpoints 1 and 2 configuration lock-out is available only when 2RE
output is installed.
RESET function configuration lock-out (rSt) is available only when
operating as counter ('Cont').
SHIFT key for MAX/MIN function configuration lock-out (MAH) is
available only when operating as tachometer ('tACH' or 'rAtE').
If 2RE output option card is uninstalled, the instrument keeps Setpoints
last configuration in memory, though it can not be visualized. There will
be no need to reconfigure Setpoints lock-out when 2RE output option is
again installed if the same configuration is required.
www.ditel.es
JR-D / JR20-D
70