"Auto-flush" function
Important!
When the "Auto-flush" function is used, a reliable water-drain must be ensured.
• The "Auto-flush" function ensures that forced flushing takes place to exchange the
water in the tap lines after 24 or 72 hours of non-use.
• The "Auto-flush" function can only be switched on with the optional remote control
(FAR Order No. 5179 0000).
• This function is switched off at the factory.
12. Controlling the Temperature
Sink mixer
with mixing lever
12.1 Set the mixing lever (a) in the desired position.
Sink mixer
with concealed mixing facility
12.2 Remove the plug (b).
12.3 Use a hollow hexagon wrench (c) to set the required mixing-water temperature.
12.4 Push in the plug.
13. Programmable Function Parameters
The optional remote control FAR Order No. 5179 00 00 offers the following functions:
– Setting the range (3–20 cm)
– Setting the turn-off delay (0–10 s)
– Activating or switching continuous operation for 3.5 min or 11 min.
– Switching off the valve
– Restoring basic settings
– Test mode for simulating without water
– Setting automatic safety switch-off (2–210 s)
– Activating automatic flushing
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. The range must thus be reduced for installations on stainless steel
washbasins that have reflecting surfaces. If this is not adequate, an additional base/
spacing ring is available (see
Chapter
20.).
7