19. Fault Correction

Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
10
Cause
– Battery dead (red LED lights up)
– Water flow regulator closed
– Grit filters are clogged with dirt
– Cleaning clip in front of the fitting
– Electronic system in sleep mode
– Solenoid valve faulty
– Solenoid valve faulty
– Corner valves not fully opened
– Grit filters are clogged with dirt
– Aerator calcified
– Supply pressure too low
– Cold water is turned off
– Filter in cold-water part is dirty
– Non-return valve faulty
– Hot water is turned off
– Filter in hot-water part is dirty
– Non-return valve faulty
Remedy
➯ Replace it
➯ Open it
➯ Clean them
➯ Remove it
➯ Shine bright light
in front of the
sensor
➯ Replace it
➯ Replace it
➯ Open them
➯ Clean them
➯ Clean it
➯ Check it
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Replace it
➯ Replace it