16. Replacing the Non-return Valve
Warning!
All non-return valves must always be replaced as a group.
Failure to observe can result in an increased bacterial load in drinking water and cause a
health risk or even risk of death.
☞
When a non-return valve is defective, the entire connector piece must be replaced. The
non-return valve is integrated in the connector piece.
16.1 Close the corner valves (c).
16.2 Trigger the valve.
16.3 Unscrew the water connector hoses (a) from the connector pieces.
16.4 Replace the connector pieces (b).
16.5 Reassemble in the reverse order.
17. Replacing the Solenoid Valve Cartridge
17.1 Close the corner valves.
17.2 Trigger the valve.
17.3 Loosen the screw (a) with a hollow hexagon wrench.
17.4 Pull the housing (b) from the base (d).
17.5 Pull off the hose sleeve (c).
17.6 Loosen the screws (f).
17.7 Remove the battery housing (e).
17.8 Remove and replace the solenoid valve cartridge (g).
17.9 Reassemble in the reverse order.
18. Changing the Battery
18.1 Pull off the housing and the hose sleeve (see
18.2 Remove the battery (a) by swivelling it out.
Important!
Use only 6 V lithium battery type CRP2.
☞
Important!
Ensure correct battery polarity when assembling.
18.3 Reassemble in the reverse order.
Chapter
17.).
9