8.
Dimensions
9.
Installation Example
10. Assembly Instructions
Warning!
Use the fitting only with non-return valves and the grit filters specified.
Failure to observe can result in an increased bacterial load in drinking water and cause a
health risk or even risk of death.
• Important!
Before installing, flush the pipes in compliance with DIN 1988.
• Do not shorten the connector hoses located at the fitting.
• Only use a 6 V lithium battery type CRP2 as a power supply.
10.1 Install the fitting (a) on the washbasin (b).
☞
Important!
Observe the range settings when installing on a stainless steel washbasin
☞
The corner valves (c) must be provided by the customer.
10.2 Insert the grit filter (d) in the corner valve.
10.3 Screw the connector piece (e) together with the non-return valve on to the corner valve.
10.4 Place the connector hose (g) with the seal (f) on to the connector piece.
11. Function
11.1 Allow your hand to approach the sensor.
• Water flows.
11.2 Remove your hand from the sensor.
• Water flow stops automatically after a set flow time.
☞
The range of the sensor and the flow duration can be adjusted with the optional remote
control (FAR Order No. 5179 0000).
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections (see
6
Chapter 13.
for range adjustment).
Chapter
13.