15. Adjusting the temperature limits.

Warning!
If the hot water supply temperature is above 45°C, the - temperature limit should be
adjusted.
Failure to observe this instruction can result in injuries due to scalding.
The temperature limit is not an active scald protection.
15.1 Remove the pressure cap (see
15.2 Carefully lever off the stop ring with a screwdriver and pull off the gear teeth by hand.
15.3 Put the pressure cap in place and trigger the fitting.
15.4 Turn the pressure cap until the desired maximum water temperature is reached.
15.5 Slide the stop ring onto the gear teeth so that the stud on the stop ring is at the right-
hand end stop of the housing.
Important!
When putting the pressure cap in place, ensure that the tappet engages with the
corresponding groove (see
15.6 Reassemble in reverse order.

16. Maintenance and care

The fitting must be checked and maintained at regular intervals depending on the
water quality and in accordance with the local conditions and rules and regulations
applicable at the site.
Maintain the following components:
• Shower head (see
• Filters (see
• Non-return valve (see
Use suitable cleaning agents which do not attack the fitting in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
Removing the shower panel
For some maintenance tasks, the shower panel must be removed.
Caution!
Do not allow the shower panel to hang by the connecting hoses.
Water connection from above:
16.1 Close the water volume regulators.
a: closed
b: open
16.2 Trigger the fitting.
8