19. Fault Correction
Fault
Water does not flow
Water flows
continuously
Water is too cold
Water flow too weak
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
20. Replacement Parts
Designation
1 Jet controller, anti-theft . . . . . . . . . 2000109128
2 Special wrench . . . . . . . . . . . . . . 2000105960
3 Solenoid valve cartridge with
grit filter . . . . . . . . . . . . . . . . . . . . 2000104456
4 Cleaning clip. . . . . . . . . . . . . . . . . 2000105795
5 Base for installation
on stainless steel washbasin . 2000105834
6 Maintenance kit comprising:
O-rings
Screws
Filters . . . . . . . . . . . . . . . . . . . 2000104898
10
Cause
– Water supply interrupted
– Voltage supply interrupted
– Solenoid valve faulty
– Grit filters are clogged with dirt
– Flow rate regulator dirty
– Cleaning clip in front of the fitting
– Electronic system in sleep mode
– Solenoid valve faulty
– Heater not heating
– Grit filters are clogged with dirt
– Water inflow not fully opened
– Grit filters are clogged with dirt
– Jet controller calcified
– Heater calcified
– Supply pressure too low
Order No.
Designation
7 Power plug . . . . . . . . . . . . . . . . . . 2000105814
8 Connector piece with
Flow rate regulator
Grit filter . . . . . . . . . . . . . . . . . . 2000109480
9 Heater . . . . . . . . . . . . . . . . . . . . . 2000109483
Accessories
10 Remote control . . . . . . . . . . . . . . . 2000101087
Extension cable
3,0 m . . . . . . . . . . . . . . . . . . . . 2000101456
10,0 m . . . . . . . . . . . . . . . . . . . 2000101457
Remedy
➯ Restore it
➯ Restore it
➯ Replace it
➯ Replace them
➯ Replace it
➯ Remove
➯ Shine bright light in
front of the sensor
➯ Replace it
➯ Test (see
manufacturer
instructions)
➯ Replace them
➯ Open it
➯ Replace them
➯ Replace it
➯ Clean it
➯ Check it
Order No.
Order No.