Hcalory SKUJ08387 Manual Del Usuario página 6

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
6.5 Remote Control Operation Instructions(NO.5)
1. Key operation instruction
On/off button----- Long press the ON / OFF button for 2 seconds to check the working status of the
heater.
Right/left button ----According to temperature control method, increase oil quantity or temperature
(adjust key according to temperature control method), low oil quantity or temperature.
2. Remote control pairing
First, the receiving part that needs + pair enters the state of waiting + pair. Then long press the power
button and the confirmation button on the remote control at the same time, the remote control appears
waiting + matching interface.
The remote control and switch enter the automatic + pairing process. If the code is successfully
matched, it will automatically exit the code matching circle.
Screen, showing normal operating parameters. If the code matching fails, it will not enter the state of
displaying the working parameters normally. If the remote control code is not received within the
timeout, it will automatically exit the matching state.
3. Temperature control mode switch
When selecting the temperature control mode through the remote control, just press (Up + (Adjust key)
at the same time, and the temperature will be displayed when switching to automatic temperature
control, and the oil quantity will be displayed if the temperature is controlled manually.
4. Working state adjustment
The working state of the heater can be adjusted at any time by remote control. Methods as below;
Left button -- Increase the pump oil volume (manual temperature control mode), or increase the set
temperature to increase the heater output temperature.
Right button --Reduce the pump oil volume (manual temperature control mode), or) lower the set
temperature to reduce the heater output temperature.
6.6 Remote Control Operation
Instructions(NO.6)
1. Key Function
Set key→Long press the setting key to enter the parameter setting
ON∕OFF→Short press to turn on, the screen will light up or there will be a voice prompt for turning
on. Long press to shut down, there is a voice prompt to shut down
- English 008 -
Up button→In the non-setting state, increase the working temperature or oil level gear, in the
setting state→up adjust the setting parameter
Down button → In the non-setting state, down adjust the working temperature or oil level,In the
setting state → lower the setting parameters
2. Manual fuel filling description
In shutdown state: short press the up key 5 times to start manual fuel filling, the screen displays the fuel
.The sound of the oil pump can be heard. The oil pump starts working. Short press the
pump icon
key to turn off manual fuel filling, the fuel pump icon disappears,and the fuel pump stops working
The process of emptying the pipeline air requires manual observation. The oil can stop when it reaches
the position of the machine's oil inlet, and too much fuel enters the machine. The ignition will emit black
smoke.
3. Description of temperature control mode switch
In the power-on state: long press the key to switch the temperature control mode, manual temperature
control (adjusting the oil volume to display L4). Automatic temperature control (adjusted temperature
display 17℃). The difference between the two temperature control methods is that the automatic pump
oil volume can reach the maximum value set by the parameter, and the machine heat is higher. The oil
volume of the manual pump is limited to the current set value, and will not hit the maximum oil volume
value set by the parameter. The gears are distinct and take into account the habits of some old drivers.
Since the sensitive temperature sensing device is installed in the controller, after the user sets the
temperature by himself, the remote control panel will automatically jump to the indoor temperature.
4. Remote control code description
In the shutdown state: long press the key to enter the remote control code matching interface, a red icon
is displayed at the top of the screen
,Press the remote control on button to transmit the remote
control code
The icon turns white,The remote control code pairing is successful. If you press the
remote control on button again, it will enter the power-on state. If the code matching fails, the icon color
does not change
. If the remote control code is not received after timeout, the remote control code
matching will be automatically exited.
5. Language switch description
In the power-on state: long press the up key to switch the language, the system defaults the language
to be English, and long press the up key in turn to switch to → Russian → German → Chinese
6. Description of parameter setting process
Enter the parameter setting → long press the up key to enter the password input interface, press the
1.
up or down key to adjust the value, and then press the set key to confirm to enter the next digit, the
following values are set in sequence, and press the set key to confirm to enter the next item
2.
Voltage setting→Press the up or down key to adjust the voltage 12V/24V. Press the set button to
confirm to enter the next item
3.
Ignition power selection→Press the up or down button to adjust the power to 6 levels, the default
value 5. It is recommended to use the default value or modify it after verification. Press the set button
to enter the next item
Fuel type selection → currently only diesel version. Press the set button to enter the next item
4.
Minimum oil volume setting → Press the up or down button to adjust the minimum pump oil volume
5.
(0.8HZ-2.5HZ). It can be modified as required. Press the set key to enter the next item.
Maximum oil volume setting → Press the up or down button to adjust the maximum pump oil volume
6.
(3.0HZ-8.0HZ). It can be modified as required. Press the set key to enter the next item.
- English 009 -
loading