Hcalory SKUJ08387 Manual Del Usuario página 5

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Remote control matching:
Method 1: In the engineering mode, press the adjustment key to adjust to the eighth item. The interface
displays "rte". At this time, press a button on the remote control to successfully match. After the match
is successful, it will automatically exit the engineering mode and return to the running interface.
Method 2: Long press the [upward adjustment key] (right upper middle) for 3s to quickly enter the
remote matching mode, the interface displays "rte" at this time, click a button on the remote control and
press a button at random to match successfully. After the match is successful Return to the running
interface since exiting the project mode.
Language selection: In the engineering mode, adjust to the ninth item, the screen displays "v---", at this
time, long press the setting key to enter the current language, press the [up/down adjustment key] to
switch and select "v-EN" as English, "v-GN" It is German, "v-RU" is Russian, "v-OF" turns off the voice,
long press the setting button to confirm the selection and automatically return to the running interface.
Pumping mode: After powering on, press and hold [Pump button] (upper left) for 7s, the pumping icon
will light up, the display area will start a 300s countdown, start pumping oil, and automatically exit when
the countdown ends. This operation needs to be completed before starting up. Cannot enter after
booting;
Screen rest mode: There is no next operation within 30s after any operation, the screen will automati-
cally rest, and the screen will turn on when you press any button.
Fault display: When the heater fails, the fault code flashes in the display area, see the table below for
fault types;
6.4 Remote Control Operation
Instructions(NO.4)
1. Function
->Setting state,increase the data;If not,increase Hz/C.
->Press1 on,Press3 off
->Setting state,decrease the data;If not,decrease Hz/°C .The basic operation uses the above,and
the settings uses the following operation:
Setting->Enter Setting state,adjust data,change working status.
->Setting state,confirm the current data,and enter the next data to set;if not,
2.
Check the Setting state(Press OK:Each time press to switch next state.)
3. Manual fueling description:
In the off state,press and hold
and OK to enter the manual fueling.-Off.After releasing,press
start the operation.You can hear the working sound of the pump and the pump icon lights up.Press to
exit the fuel fill and the pump icon disappears.The process of emptying air from the pipe line
needs to be observed.When the oil reaches the position of the oil in let of the machine,it can stop.Exces-
sive fuel enters the machine and there will be black smoke.
- English 006 -
4. The switching description of Temperature control mode:
Press and hold the
mode,manual temperature control,automatic temperature control The difference between the two
temperature control methods is that the automatic mode pump oil can reach the maximum value of the
parameter setting,the machine heat is higher,the manual mode pump oil quantity is limited to the current
set value,and the parameter setting maximum oil quantity value will not be reached
5. The match of Remote control and LCD:On the"off"state.First,press the"power"and"confirm"button
simultaneously on Remote controller until LCD screen displaying"wait for matching".Second,press
off"and"on"buttonontheLCDscreenfor3~5seconds,then the screen will enter the"matching"interface.Af-
ter match,it will exit
automaticallyanddisplaythenormalworkingparameters.Any match failure,no displaying about the normal
working parameters.Over time fail to match,exit the"matching"interface automatically also.
6. Parameter setting description(press the setting button to enter the setting state)
Time setting---Press the on or off button to adjust the parameters---Set the hour(24hoursystem),min-
1)
ute and other parameters,press the confirm button,then enter to the next interface.
Timing power-on Setting----Default off,display off,press on button then show the off,press confirm
2)
button--Set hours and minutes in turn,timing by count down,Max be 99minutes and 59seconds.
Timing power-off Setting---Default off,display off,press on button then show the off,press confirm
3)
button--Set hours and minutes in turn,timing by countdown,Max be 99minutes and 59seconds.
Input manage passport--Press the"on"or"off"button until it reach the correct value,then press the
4)
confirm button enter next interface,Any input error,it will comeback to the first digit.then no need to
modify subsequent data,press the set button until exit,or wait for 10 seconds for exiting automatical-
ly.
Pump oil flow setting---Press the"on"or"off"button to adjust minimum pumping oil flow.after reach the
5)
value,press confirm button to set the max oil flow----Press the"on"or"off"button to adjust maximum
pumping oil flow.after reach the value,press confirm button to enter next interface.
Fan speed setting---Press the"on"or"off"button to adjust min speed.after reach the value,press
6)
confirm button to set the max speed.Press the"on"or"off"button to adjust max speed.after reach the
value,press confirm button to enter next interface.
7)
Ignition plug power selection ----------mother board operating voltage can be only selected
under"off"state!Press the"on"or"off"button to switch--Set the working voltage,adjust the 12V system
to display V-12,adjust the 24V system to display V-24,finish select.Please check the match status
of oil pump,motor and ignition plug before turn-on.
---------Display5N-1,Press the"on"or"off"button to set the speed signal,same polarity for 2 magnets
on impeller,select 5N-2,different polarity for 2magnets on impeller or only 1magnet (Defaults),select
5n-1.Any error for this parameters, 1times difference for the speed will lead to!
Ignition
plug
power
8)
value(1=35W,2=40W,3=45W,4=80W,5=85W,6=90W)Default value kindly recommend use the
default value or modify the value after verification.
Manage password modification---Initial display off status,no need to change,press confirm button to
9)
skip the password modification,and save above modified parameters.Press the on button when
modifying.Display oN status,press to confirm and enter the password modification status,press the
on or off button to adjust.Afterthe4-digit password is entered correctly,press confirm button to enter
next interface.After saving the new password and adjusting the setting parameters,it will exit
automatically.
to
up and set keys
at the same time to switch the temperature control
selection,dispalyRF-5,press
the"on"or"off"button,modify
- English 007 -
the
Tabla de contenido
loading