• that the plant is fitted with an efficient earth connection, following the standards and law provisions in
force.
The earth connection is compulsory in terms of the law. Should there be no cable and/or plug on the
equipment, use suitable absorption material for the working temperature as well, as indicated on the
matrix plate. Under no circumstance must the cable reach a temperature above 50 °C of the ambient
temperature.
Should a direct connection to the network be required, it will be necessary to interpose an omnipolar
switch with minimum aperture between the 3 mm. contacts, dimensioned to bear the plate load and it
must follow the standards in force (the yellow/green earth cable must not be interrupted by the switch).
The plug or omnipolar switch must be easily reached on the installed equipment.
The manufacturers decline any responsibility in the event of non-compliance with what is described
above and the accident prevention norms not being respected and followed.
If the mains cable becomes damaged, replace it immediately with a cable or special cable set obtained
from the manufacturer or from after sales service.
Adaptation to various types of gas
(Fig. 6) Should the appliance be pre-set for a different type of gas than that available, proceed as follows:
• replace the injectors (Fig. 6) with the corresponding type of gas to be used (see table "Injectors
characteristics").
• to adjust to the minimum, use a screwdriver on the screw placed on the tap (Fig. 8) after turning the tap
to its minimum position. For LPG (butane/propane) screw tight.
24