3.2
Intended use
The product described is a charger for the FX 3-A welding machine. It is designed to be connected to power
outlets providing an AC (alternating current) voltage of 100 to 127 volts or 220 to 240 volts (depending on
country-specific version). Observe the information on the type identification plate of your charger.
More information is available from your Hilti Store or from www.hilti.group
•
3.2.1
Foreseeable misuse
Never try to use the product to charge other batteries or products other than the Hilti FX 3-A.
3.3
Using extension cords
The use of an inappropriate extension cord can lead to risk of fire and electric shock. If the use of an
extension cord is necessary, make sure that
•
the pins of the extension cord connector are of the matching number, size and shape to mate with the
connector of the charger,
•
the extension cord is correctly wired and in good electrical condition,
•
the conductor gauge is adequate for the charger's AC amperage.
3.3.1
Maximum length of an extension cord
AWG 16
7.6 m
3.3.2
Overcharge protection
The product has overcharge protection. When the battery is fully charged the charger automatically switches
to the maintenance mode.
3.4
Items supplied
Charger, operating instructions
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4
Technical data
Supply frequency
Mains (AC) voltage
Maximum supply current
Maximum AC supply fuse rating
Maximum output power
Maximum output current (DC)
Protection class (with protective earth)
10
English
AWG 12
15.2 m
AWG 10
30.5 m
220240 V
110120 V
100 V
220240 V
110120 V
100 V
220240 V
110120 V
100 V
220240 V
110120 V
100 V
220240 V
110120 V
100 V
220240 V
110120 V
100 V
2302421
*2302421*
AWG 8
45.6 m
C 53
50 Hz ... 60 Hz
50 Hz ... 60 Hz
50 Hz ... 60 Hz
220 V ... 240 V
110 V ... 120 V
100 V
9.5 A
15 A
15.7 A
16 A
20 A
16 A
1,040 W
1,000 W
840 W
18 A
18 A
18 A
I