Jumper off (jumper link removed or
(parked) on one pin), the internal
magnet switch is in use (factory default)
8.
Operation
LED Indicator
In normal operation mode, the LED will not light.
When the door contact is in low battery condition, every time the
door contact is activated (device opened/ closed), the LED will
light on for 2 seconds.
When the cover is opened and the tamper switch is violated, the
LED will light on for 2 seconds. When a tamper condition persists,
every time the door contact is activated, the LED will light on for 2
seconds.
When the device contact is in test mode, the LED will flash every
time it is activated.
Test mode
Each press of the test button causes the door contact to transmit
a radio range test signal to the control panel and will enter the
test mode for 3 mins. When the test signal is transmitted, the led
will flash to confirm signal receipt by the control panel.
Each additional test button press will extend test mode another 3
mins.
9.
Self test
After installation, the door contact will send self test signals to the
control panel at random intervals of 30 to 50 minutes.
If the control panel does not receive self test signals from the
contact, the panel will display an error message.
Refer to the section Supervision in chapter Special Settings of the
control panel manual.
10. Technical Specifications
power supply
frequency
operating temperature
humidity
V. 01 – 12/06/2013
CTC1000DS
1 x 3.6 V lithium 1/2 AA battery (incl.)
868.6375 MHz
-20 to 50 °C
up to 95 % non-condensing
9