Velleman CTC1000DS Manual Del Usuario página 9

Contacto de puerta/ventana para ctc1000
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
Jumper off (jumper link removed or
(parked) on one pin), the internal
magnet switch is in use (factory default)
8.
Operation
LED Indicator
 In normal operation mode, the LED will not light.
 When the door contact is in low battery condition, every time the
door contact is activated (device opened/ closed), the LED will
light on for 2 seconds.
 When the cover is opened and the tamper switch is violated, the
LED will light on for 2 seconds. When a tamper condition persists,
every time the door contact is activated, the LED will light on for 2
seconds.
 When the device contact is in test mode, the LED will flash every
time it is activated.
Test mode
 Each press of the test button causes the door contact to transmit
a radio range test signal to the control panel and will enter the
test mode for 3 mins. When the test signal is transmitted, the led
will flash to confirm signal receipt by the control panel.
 Each additional test button press will extend test mode another 3
mins.
9.
Self test
 After installation, the door contact will send self test signals to the
control panel at random intervals of 30 to 50 minutes.
 If the control panel does not receive self test signals from the
contact, the panel will display an error message.
 Refer to the section Supervision in chapter Special Settings of the
control panel manual.
10. Technical Specifications
power supply
frequency
operating temperature
humidity
V. 01 – 12/06/2013
CTC1000DS
1 x 3.6 V lithium 1/2 AA battery (incl.)
868.6375 MHz
-20 to 50 °C
up to 95 % non-condensing
9