Installation - New Construction with Flex Bracket
CAUTION:
Make sure power is switched off at
service panel before starting installation.
Wear gloves during installing to help protect your
hands from injury.
NOTE: Ceiling mount only.
IMPORTANT:
Please remove the tape, which protects
the damper during shipping and
installation, from the duct adaptor as
shown below.
1
Install the flex bracket
Bend down 4 tabs on the side of flex bracket (G) for
positioning, pre-install the flex bracket to joists by
using 2 screws (D) on one side.
Adjust the length of flex bracket (G) to fit the spacing
between the joists (12in. to 22in.). Attach the flex
bracket with the other 2 screws (D).
Please make sure the bottom of the flex bracket will
be flush with the bottom of the joists.
2
Adjust the tabs of fan housing
Pull the 4 tabs (AA) of the fan housing into the vertical position.
3
Install the fan housing on bracket
Align the 4 tabs (AA) on the fan housing through the slots on the
flex bracket (G). Then insert the tabs through the slots until the
fan housing (A) sitting on the flex bracket (G).
Then bend the tabs (AA) to both sides to attach the fan housing
firmly on the flex bracket (G).
G
7
Please contact 1-800-841-1350 for further assistance.
D
AA
A
G
AA
HAMPTONBAY.COM