Roca NEOBIT 24/24 Instrucciones De Funcionamiento página 7

Caldera mural de gas
Limpieza filtro / Cleaning the filter / Nettoyage filtre
Filterreinigung / Pulizia del filtro / Limpeza do filtro
1
Cerrar la llave de paso de ACS.
Abrir los grifos para vaciar el circuito de ACS.
Close the DHW installation valve. Open the taps to
empty the DHW installation.
Fermer la clé de pas d'ECS. Ouvrir les robinets pour
vider le circuit d'ECS.
Schließen Sie das Warmewasser Installation Ventil.
Öffnen Sie die Hähne, um die Warmewasser
Installation zu leeren.
Chiudere la valvola dell'installazione dell'ACS. Aprire
i rubinetti per svuotare l'installazione dell'ACS.
Fechar a válvula da instalação de AQS
Abrir os torneiras para esvaziar o circuito de AQS.
Códigos anomalías / Fault codes / Codes d'anomalie
Störungscodes / Codici di anomalie / Código de anomalia
ES
Si se encienden los leds de temperatura (A) junto con el
led de anomalía (B) significa que la caldera está
bloqueada por alguna anomalía. Tome nota de los que se
encienden y llame a su instalador o a nuestro servicio
técnico. No obstante, si la combinación de pilotos que
se enciende es alguna de las siguientes, antes de llamar
puede hacer lo siguiente:
60-70-90 ó 40-80-90: Puede ser que no llegue gas a la
caldera. Verifique si alguna llave de paso del gas está
cerrada. Una vez subsanada la anomalía, gire el
conmutador a la posición
R ,
servicio deseado y la caldera intentará reanudar el
servicio.
40-50-60-70-90: Ha actuado el dispositivo de evacuación
de los gases de la combustión, por una momentánea
inversión de los mismos o una deficiente salida. Espere
unos 15 minutos para la reposición automática del servicio
y luego gire el conmutador a la posición R , vuelva a
girarlo al servicio deseado y si se repite la anomalía
avise al técnico.
50-60-90: Ha actuado el dispositivo de seguridad por
sobretemperatura en el circuito primario y se debe purgar
el aire de la instalación. La caldera entra en un estado
transitorio durante el cual el led de temperatura parpadean.
Al enfriarse el dispositivo de sobretemperatura, los leds
quedan fijos. Se debe purgar la caldera y los radiadores
y girar el conmutador a la posición R. A continuación,
vuelva a girarlo al servicio deseado y la caldera intentará
reanudar el servicio.
40-50-90: Falta de presión en el circuito de Calefacción.
Llenar el circuito y luego cerrar bien el grifo de llenado.
Solicitar directamente servicio
2
Desmontar el filtro y limpiarlo.
Disassemble the filter and clean it.
Démonter le filtre et le nettoyer.
Bauen Sie den Filter auseinander
und säubern Sie ihn.
Smontare il filtro e pulirelo
Desmontar o filtro e limpá-lo
GB
If one lights the leds temperature (A) with the led
d'anomalie (B) it means that the boiler is blocked by a
certain anomaly. Please take note of the lamps that
light up and call your installer or Roca's nearest After-
Sales Service. However, if the lamps that light up are as
indicated below, before calling you may try to rectify the
faulty condition yourself as follows:
60-70-90 or 40-80-90: This means that burners fail to light
up due to the lack of gas. Check if any of the gas inlet
cocks is closed. Once the fault has been cleared, turn the
vuelva a girarlo al
service selector switch to the position marked R , rotate
it to the wanted service again and then the boiler will
attempt to light up again.
40-50-60-70-90: This means that the evacuation control
device for the products of combustion has been activated
due to a momentary backflow or irregular outlet of flue
gases. Wait about 15 minutes for an automatic resumption
of the service concerned and then turn the service selector
switch to the position marked R , rotate it to the wanted
service again and if this happens again, call your nearest
After-Sales Service office.
50-60-90: The thermostat has actuated by overheat in
the primary circuit and the air of the installation must be
vented. The boiler starts a transitory state during which
the temperature LED's blink. When the thermostat cool
down, the LED's get fixed. It must vent each radiator and
the boiler and turn the commutator to position R. Then,
turn it again to the desired service and the boiler will try
to resume the service.
40-50-90: Lack of pressure in the circuit of Heating. Fill
the circuit and then turn off well the filling tap. Finally,
ask for service directly.
3
Volver a montar el filtro y abrir la llave de paso
de ACS.
Mount the filter again and open the installation
valve of ACS.
À monter le filtre et ouvrir à nouveau la clé de
pas d'ACS.
Bringen Sie den Filter wieder an und öffnen Sie
das instalation Ventil von ACS.
Monti ancora il filtro ed apra la valvola
d'installazione di ACS.
Monte o filtro outra vez e abra a válvula da
instalação de AQS.
FR
Si on allume les leds de température (A) avec le led
d'anomalie (B) il signifie que la chaudière est bloquée
par une certaine anomalie. Prendre note de celles qui
s'allument et appeler l'installateur ou notre service
technique. Cependant, si la combinaison de lampes
témoin allumées est l'une des suivantes, avant
d'appeler, on peut porcéder de la façon suivante:
60-70-90 ou 40-80-90: Il est probable que le gaz n'arrive
pas à la chaudière. Vérifier si quelque vanne de passage
du gaz n'est pas fermée. Une fois cette anomalie corrigée,
tourner le commu-tateur vers la position R , tournez-le
enore au service desiré et la chaudière essaiera de
redonner le service.
40-50-60-70-90: Le dispositif d'évacuation des gaz de la
combustion s'est activé à cause d'une inversion
momentanée de ceuxci ou d'une sortie défectueuse.
Attendre environ 15 minutes pour la remise en service
automatique et tourner ensuite le commutateur vers la
position R , tournez-le enore au service desiré et si l'
anomalie se reproduit, prévenir le technicien.
50-60-90 : Le dispositif de sécurité a été actionné par
surchauffe dans le circuit primaire et on doit purger l'air
de l'installation. La chaudière rentre dans un état
transitoire pendant lequel les leds de temperature clignote.
Quand le dispositif se refroidit, les leds restent fixes. Il
faut purger les radiateurs et la chaudière et tourner le
sélecteur à la position R. Ensuite, tournez le sélecteur
encore au service souhaité et la chaudière essayera de
reprendre le service.
40-50-90 : Manque de pression dans le circuit de
Chauffage. Remplir le circuit et fermer ensuite bien le
robinet de remplissage. Solliciter directement service.
7
loading

Este manual también es adecuado para:

Neobit 24/24 f