Steinberg Systems SBS-PW-60/5N Manual De Instrucciones página 29

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
10. P10 x Intensity of digital filtering
X = 1: high
X = 2: average
X = 3: low
X = 4: very slow
11. P11 X Stabilization time
X = 1: high
X = 2: average
X = 3: low
12. P12 X Stability range
X = 1: low
X = 2: average
X = 3: high
13. P13 X Strength of the animal scale function
X = 1: low
X = 2: average
X = 3: high
14. P14 X Animal scale function ON/OFF
X = 0: OFF
X = 1: ON (go to the animal scale function by briefly pressing the "*" key)
15. P15 X Print transmission format - not applicable
X = 1: Default Weight: 1.234 kg
X = 2: 1.234
X = 3: = 432,100
X = 4: Tare, Gross Weight, Net Weight sent at once
X = 5: ST, NT 1.234 kg
16. P16 X Turn on/off alarm lamp
X = 1: OFF
X = 2: ON
17. P17 X Creep on/off
X = 1: OFF
X = 2: ON
18. P18 X Error compensation: 0 means off, other means x.