Bosch Climate 3000i CL3000iU W 26 E Manual De Instalación página 55

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
5.2
Faults not indicated
Fault
The output of the indoor unit is too low.
Outdoor unit or indoor unit is not working.
Outdoor unit or indoor unit starts and stops
continuously.
1) A fuse for the overcurrent protection is located on the main PCB. The specification is printed on the main PCB and can also be found in the technical data on page 56.
Table 71
6
Environmental protection and disposal
Environmental protection is a fundamental corporate strategy of the
Bosch Group.
The quality of our products, their economy and environmental safety are
all of equal importance to us and all environmental protection legislation
and regulations are strictly observed.
We use the best possible technology and materials for protecting the
environment taking account of economic considerations.
Packaging
Where packaging is concerned, we participate in country-specific
recycling processes that ensure optimum recycling.
All of our packaging materials are environmentally compatible and can be
recycled.
Used appliances
Used appliances contain valuable materials that can be recycled.
The various assemblies can be easily dismantled. Synthetic materials are
marked accordingly. Assemblies can therefore be sorted by composition
and passed on for recycling or disposal.
Old electrical and electronic appliances
This symbol means that the product must not be disposed
of with other waste, and instead must be taken to the waste
collection points for treatment, collection, recycling and
disposal.
The symbol is valid in countries where waste electrical and
electronic equipment regulations apply, e.g. "(UK) Waste Electrical and
Electronic Equipment Regulations 2013 (as amended)". These
regulations define the framework for the return and recycling of old
electronic appliances that apply in each country.
As electronic devices may contain hazardous substances, it needs to be
recycled responsibly in order to minimize any potential harm to the
environment and human health. Furthermore, recycling of electronic
scrap helps preserve natural resources.
For additional information on the environmentally compatible disposal
of old electrical and electronic appliances, please contact the relevant
local authorities, your household waste disposal service or the retailer
where you purchased the product.
You can find more information here:
www.weee.bosch-thermotechnology.com/
Climate 3000i – 6721823680 (2023/01)
Possible cause
Heat exchanger of the outdoor or indoor unit
contaminated or partially blocked.
Shortage of refrigerant
No current
Leakage protector or fuse installed in the
1)
device
has blown.
Insufficient refrigerant in the system.
Too much refrigerant in the system.
Moisture or impurities in the refrigerant circuit.
Voltage fluctuations too high.
Defective compressor.
Refrigerant R32
Refrigerant is hazardous to the environment and must be collected and
disposed of separately.
7
/ UK GDPR), to fulfil our duty of product surveillance and for product
safety and security reasons (art. 6 (1) sentence 1 (f) GDPR / UK GDPR),
to safeguard our rights in connection with warranty and product
registration questions (art. 6 (1) sentence 1 (f) GDPR / UK GDPR) and to
analyze the distribution of our products and to provide individualized
information and offers related to the product (art. 6 (1) sentence 1 (f)
GDPR / UK GDPR). To provide services such as sales and marketing
services, contract management, payment handling, programming, data
hosting and hotline services we can commission and transfer data to
external service providers and/or Bosch affiliated enterprises. In some
cases, but only if appropriate data protection is ensured, personal data
might be transferred to recipients located outside of the European
Economic Area and the United Kingdom. Further information are
provided on request. You can contact our Data Protection Officer under:
Data Protection Officer, Information Security and Privacy (C/ISP),
Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY.
You have the right to object, on grounds relating to your particular
situation or where personal data are processed for direct marketing
purposes, at any time to processing of your personal data which is based
on art. 6 (1) sentence 1 (f) GDPR / UK GDPR. To exercise your rights,
1) Based on ANNEX I of REGULATION (EU) No 517/2014 of the European
Parliament and of the Council of 16 April 2014.
Environmental protection and disposal
Remedy
▶ Clean heat exchanger of outdoor or indoor
unit.
▶ Check tightness of pipes, reseal if required.
▶ Refill refrigerant.
▶ Check power connection.
▶ Power on the IDU.
▶ Check power connection.
▶ Check the leckage protection and fuse.
▶ Check tightness of pipes, reseal if required.
▶ Refill refrigerant.
Remove refrigerant with refrigerant recovery
unit.
▶ Evacuate refrigerant circuit.
▶ Fill with new refrigerant.
▶ Install voltage regulator.
▶ Replace compressor.
The appliance contains fluorinated gas R32 (global warming
1)
potential 675
) mild combustibility and low toxicity (A2L
or A2).
Contained quantity is indicated on the equipment outdoor
unit name label.
Data Protection Notice
We, Bosch Thermotechnology Ltd., Cotswold Way,
Warndon, Worcester WR4 9SW, United Kingdom
process product and installation information,
technical and connection data, communication data,
product registration and client history data to provide
product functionality (art. 6 (1) sentence 1 (b) GDPR
55
loading

Este manual también es adecuado para:

Climate 3000i cl3000iu w 35 eClimate 3000i cl3000iu w 53 eClimate 3000i cl3000iu w 70 eClimate 3000i cl3000i 26 eClimate 3000i cl3000i 35 eClimate 3000i cl3000i 53 e ... Mostrar todo