ALHENA TECH C
Installer menu [SERVICE]
ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAM-
ETERS.
Access the Main menu [MENU] with the button
Follow the path installer menu [Service] >enter the Password 1234 (see fig. 17). Confirm with
the button
.
Parameter modification menu [TSP]
Press the heating buttons to scroll the list, press the button
press the DHW, buttons, confirm with the button
Table 10- Transparent Parameters Table
Index Description
b01 Boiler type selection
b02 Boiler type
b03 Gas type
System water pressure protection
b04
selection
b05 Summer/Winter mode
Variable input contact operation selec-
b06
tion
b07 Relay card LC32 operation selection
b08 Hours without DHW draw-off
b09 Fault 20 status selection
b10 Not implemented
b11 Flowmeter timing
b12 Comfort mode
b13 Not implemented
b14 DHW factor
b15 Flowmeter type selection
.
Range
3 = HEATING ONLY COMBI (DO NOT MODIFY)
1 = 24 kW
2 = 28 kW
3 = 34 kW
4 = Do not use
5 = Hybrid 24 C
6 = Hybrid 28 C
7 = Hybrid 34 C
0 = Natural gas
1 = Liquefied gas
2 = Propane-air
0 = Pressure switch
1 = Pressure transducer
0 = WINTER - SUMMER - OFF
1 = WINTER - OFF
0 = Flowmeter exclusion
1 = System thermostat
2 = Second room therm.
3 = Warning/Alert
4 = Safety thermostat
0 = External gas valve
1 = Alarm
2 = System filling solenoid valve
3 = Solar 3-way valve
4 = Second heating pump
5 = Alarm2
6 = Burner lit
7 = Frost protection On
0 ÷ 24 hours
(time for temporary deactivation of comfort mode without draw-off
with b012 = 0)
0 = Deactivated
1 = Enabled (only for versions with pressure transducer)
--
0 = Deactivated
1-10 = seconds
0 = Activation with draw-off
1 = Always active
--
0 - 1
1 = Flow. (450 imp/l)
2 = Flow. (700 imp/l)
3 = Flow. (190 imp/l)
cod. 3541V512 - Rev 00 - 07/2022
to display the value. To modify,
or cancel with the button
.
Default
3
1 = 24 kW
2 = 28 kW
3 = 34 kW
4 = /
5 = Hybrid 24 C
6 = Hybrid 28 C
7 = Hybrid 34 C
0
1
0 = Enabled
2
0
24
0
--
0
0
--
0
3
319