Error messages and error clearance
Message/symptom
No vacuum at desoldering tool
Insufficient vacuum at desoldering tool
Hot air tool has no air
Technical Data
Dimensions L x W x H
Weight
Mains supply voltage
Power consumption
Safety class
Fuse
max. Vacuum
Maximum quantity supplied
Ambient temperature
Subject to technical alterations and amendments.
Possible cause
Vacuum not connected
•
Desoldering nozzle clogged
•
Pump faulty
•
Filter cartridge on desoldering tool
•
full
Main filter full
•
Air hose not connected
•
Main filter full
•
WXair
197 mm x 153 mm x 86 mm
7,75 inch x 6,02 inch x 3,38 inch
1,4 kg
100-240 V AC 50/60 Hz;
70 W
I, antistatic housing
T4A
70 kPA
18 l/min
10 - 40°C
ENGLISH
Remedial measures
Connect vacuum hose to vacuum
•
connection
Service desoldering nozzle using
•
cleaning tool
Change filter cartridge on desoldering
•
tool full
Change the main filter element on the
•
soldering station
Connect or check air hose
•
Change main filter cartridge on
•
soldering station
EN
23