Section 2
3.
Mount the LuminIce® and transformer
to the mounting bracket.
• Mount the components on the opposite
side of the bracket lip. The bracket
lip will slide between the top rail and
insulation when mounted.
• LuminIce® - The bulb and bulb wiring
must face up to allow bulb replacement
with the LuminIce® in place. Mount the
LuminIce® on the left side of the bracket.
• Power supply - Mount the power supply
to the right of the LuminIce®.
4.
Install mounting plate in ice machine
and secure with fasteners. The
mounting plate has pass-through holes
for the hose adapters.
Part Number: 000014110 Rev 01 1/19
5.
Disconnect L1 & N wires and install L1
& N of wiring adapter to the incoming
power supply wires. Connect removed
wires and LuminIce® wires to adapter.
Wires Removed From Contactor
LuminIce® Power
6.
Route transformer low voltage wiring
(black and yellow wires) to the
LuminIce®. Snap the wire harness
connectors together. Bundle and
secure any excess low voltage wires
near the transformer.
7.
Cut the LuminIce® hose to length and
attach:
NOTE: The upper bulkhead adapter
connects to the upper connector on the
LuminIce® and the lower bulkhead adapter
connects to the lower LuminIce® connector.
• Insert tubing onto the lower bulkhead
adapter and dry fit to establish length,
then cut to fit. Attach to LuminIce® and
secure with snap clamp.
• Insert tubing onto the upper bulkhead
adapter and dry fit to establish length,
then cut to fit. Attach to LuminIce® and
secure with snap clamp.
• Reinstall the evaporator dust cover.
8.
Test run:
• Install all panels except the front panel.
• Restore power - The LuminIce® is
energized whenever power is applied to
the ice machine. A noticeable draft will
be emitted from the upper hose adapter
during operation.
Installation
N
L1
Incoming
Power Supply
21