7.4 Storage
Warning!
G
Disconnect the plug from the socket, vent the
B
appliance and tools connected to it and empty the
condensate.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which is
not accessible to unauthorized persons.
Always store upright, never tilted!
9. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
Fault
The compressor stops and restarts
automatically after a few minutes.
After a few attempts to restart, the
compressor stops.
The compressor does not stop and
the safety valve is tripped.
Any other type of operation must be carried out by authorized Service Centers, requesting original
parts. Tampering with the machine may impair its safety and in any case make the warranty null
and void.
8. DISPOSAL AND RECYCLING
waste electrical and electronic equipment (WEEE).
The symbol carrying a crossed-out refuse container
depicted on any equipment or the relative packaging
means that, at the end of its useful life, said product must
be disposed of separately from other waste.
The user must therefore take said equipment to the
centres specialising in differentiated refuse collection of
electric and electronic equipment or alternatively return
it to the reseller when purchasing a new similar piece of
equipment.
Thanks to differentiated refuse collection, discarded
equipment can be sent to be recycled, treated and disposed
of in an environmentally-friendly manner; this helps
avoiding possible negative effects on the environment
and on health and promotes the re-employment and/or
recycling of the equipment's materials.
Any unauthorised disposal of the product by the user will
result in the application of the fines provided for by the
regulations in force.
Cause
Tripping of the thermal cutout due to
overheating of the motor.
Tripping of the thermal cutout due to
overheating of the motor (removal
of the plug with the compressor
running, low power voltage).
Irregular compressor operation or
pressure switch malfunction.
18
Pursuant to Directive 2012/19/EU on
Remedy
Clean the air ducts in the shroud.
Ventilate the work area.
Activate the I/O switch (On/Off).
Ventilate the work area. Wait a few
minutes. The compressor will restart
independently.
Remove the plug and contact the
Service Center.