1 About This Documentation

1.1 Documentation validity

This documentation applies to the AV series IO-Link interface. It applies to both
the type A (3-wire) and type B (5-wire, external actuator supply) interface.
The documentation is geared toward programmers, electrical engineers, service
personnel, and system owners.
This documentation contains important information on the safe and proper com-
missioning and operation of the product and how to remedy simple malfunctions
yourself. In addition to a description of the interface, it also contains information
on the configuration of the IO-Link interface.

1.2 Required and supplementary documentation

Only commission the product once you have obtained the following docu-
u
mentation and understood and complied with its contents.
Table 1: Required and supplementary documentation
Documentation
System documentation
Documentation of the IO-Link-Mas-
ter configuration program
Assembly instructions for all current
components and the entire AV valve
system
System description for electrically
connecting the IO-Link interface
All assembly instructions and system descriptions for the AV series, as
well as the configuration files, can be found on the CD R412018133.

1.3 Presentation of information

1.3.1 Warnings
In this documentation, there are warning notes before the steps whenever there
is a risk of personal injury or damage to equipment. The measures described to
avoid these hazards must be followed.

Structure of warnings

Hazard type and source
Consequences
Precautions
u
Meaning of the signal words
Immediate danger to the life and health of persons.
Failure to observe these notices will result in serious health consequences, in-
cluding death.
Possible danger to the life and health of persons.
Failure to observe these notices can result in serious health consequences, in-
cluding death.
Possible dangerous situation.
Failure to observe these notices may result in minor injuries or damage to
property.
Possibility of damage to property or malfunction.
Failure to observe these notices may result in damage to property or malfunc-
tions, but not in personal injury.
AVENTICS™ | R412018154-BAL-001-AA | English
Document type
Comment
Operating instruc-
To be created by system owner
tions
Software manual
Scope of delivery of the master
manufacturer/controller manu-
facturer
Assembly instruc-
Printed documentation
tions
System descrip-
PDF file on CD
tion
SIGNAL WORD
DANGER
WARNING
CAUTION
NOTICE

1.3.2 Symbols

Recommendation for the optimum use of our products.
Observe this information to ensure the smoothest possible operation.

1.4 Designations

The following designations are used in this documentation:
Table 2: Designations
Designation
Meaning
IO-Link interface
IO-Link module with integrated valve drivers
IO-Link master
Point-to-point communication partner to the IO-Link interface

1.5 Abbreviations

This documentation uses the following abbreviations:
Table 3: Abbreviations
Abbreviation
Meaning
AV
Advanced Valve
IODD
Device master data (IO Device Description)
n.c.
not connected
PLC
Programmable Logic Controller or PC assuming control functions
UA
Actuator voltage (power supply for valves and outputs)

2 Notes on Safety

2.1 About this chapter

The product has been manufactured according to the accepted rules of current
technology. Even so, there is danger of injury and damage to equipment if the
following chapter and safety instructions of this documentation are not followed.
1. Read these instructions completely before working with the product.
2. Keep this documentation in a location where it is accessible to all users at all
times.
3. Always include the documentation when you pass the product on to third par-
ties.

2.2 Intended use

The AV series IO-Link interface with integrated multipole board is an electronic
component and was developed for use in the area of industrial automation tech-
nology.
It serves to connect valves to the IO-Link communication system. The IO-Link in-
terface should only be connected to a master of the same type (type A to type A,
type B to type B).
NOTICE:If connecting a type B IO-Link interface to a type A master:
Make sure that the external supply is never connected to the SIO pin on the
u
type A master.
The AV series IO-Link interface may only be used to control AV03 and AV05
valves.
The IO-Link interface is intended for professional use only and not for private use.
The IO-Link interface may only be used for industrial applications (class A). An in-
dividual license must be obtained from the authorities or an inspection center for
systems that are to be used in a residential area (residential, business, and com-
mercial areas). In Germany, these individual licenses are issued by the Regulating
Agency for Telecommunications and Post (Regulierungsbehörde für Telekommu-
nikation und Post, Reg TP).
The IO-Link interface may be used in safety-related control chains if the entire
system is geared toward this purpose.
Observe the documentation R412018148 if you use the valve system in
u
safety-related control chains.

2.2.1 Use in explosive atmospheres

The IO-Link interface is not ATEX-certified. ATEX certification can only be granted
to complete valve systems. Valve systems may only be operated in explosive at-
mospheres if the valve system has an ATEX identification!
Always observe the technical data and limits indicated on the name plate for
u
the complete unit, particularly the data from the ATEX identification.Always
17