Field Settings - EAS ELECTRIC EMCH Serie Manual De Instrucciones

Ocultar thumbs Ver también para EMCH Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Screw hole installed on
the three M4X20
Screw hole installed on
86 Electrician box, use
two M4X25
1) Use straight head screwdriver to insert in the buckling
position in the bottom of wired controller, and spin the
screwdriver to take down the back cover. (Pay attention to
spinning direction, otherwise will damage the back cover!)
2) Use three M4X20 screws to directly install the back
cover on the wall.
3) Use two M4X25 screws to install the back cover on the 86
electrician box, and use one M4X20 screws for fixing on
the wall.
4) Adjust the length of two plastic screw bars in the
accessory to be standard length from the electrical box
screw bar to the wall. Make sure while installing the screw
bar to the wall, making it as flat as the wall.
5) Use cross head screws to fix the wired controller bottom
cover in the wall through the screw bar. Make sure the
wired controller bottom cover is on the same level after
installation, and then install the wired controller back to
the bottom cover.
6) Over fastening the screw will lead to deforma tion of back
cover.
A
Cutting place of
left down side
wire outlet
B
Wiring
60mm
hole
Back cover
Signal
switching
wires
Left down
side wire
outlet
C
Wall hole and wiring
hole Diameter: Φ8--
Φ10
Putty
Trap
Avoid the water enter into the wired remote controller,
use trap and
putty
wires during wiring installation.
10.4.4 Front cover installation
After adjusting the front cover and then buckle the
front cover; avoid
clamping
switching wire during installation.
Correct install the back cover and firmly buckle the front
cover and back cover, otherwise will make the front cover
drop off.

10.5 Field settings

The unit should be configured to match the installation
environment (outdoor climate, installed options, etc.)
and user demand. A number of field settings are
available. These settings are accessible and program-
mable through "FOR SERVICEMAN" in user interface.
Powering on the unit
When the unit is powered on, "1%~99%" is displayed on
the user interface. During this process the user
interface cannot be operated.
Procedure
To change one or more field settings, please refer to
"FOR SERVICEMAN" for details
Temperature values displayed on the wired
controller (user interface) are in °C.
38
Putty
Putty
Trap
Trap
to
seal
the
connectors